Type | Programmable scientific |
---|---|
Manufacturer | Hewlett-Packard |
Introduced | 1988 |
Discontinued | 1995 |
Calculator | |
Entry mode | RPN |
Precision | 12 display digits (15 digits internally), exponent ±499 |
Display type | LCD dot-matrix |
Display size | 2 lines, 22 characters, 131×16 pixels |
CPU | |
Processor | Saturn (Lewis) |
Programming | |
Programming language(s) | RPN key stroke (fully merged) |
Firmware memory | 64 KB of ROM |
Program steps | 7200 |
Interfaces | |
Ports | IR (Infrared) printing |
Other | |
Power supply | 3×1.5 V button cell batteries (Panasonic LR44, Duracell PX76A/675A or Energizer 357/303) |
Weight | 6 oz (170 g) |
Dimensions | 148×80×15 mm |
The HP-42S RPN Scientific is a programmable RPN Scientific hand held calculator introduced by Hewlett-Packard in 1988. It is a popular calculator designed for science and engineering students.
Overview
Perhaps the HP-42S was to be released as a replacement for the aging HP-41 series as it is designed to be compatible with all programs written for the HP-41. Since it lacked expandability, and lacked any real I/O ability, both key features of the HP-41 series, it was marketed as an HP-15C replacement.
The 42S, however, has a much smaller form factor than the 41, and features many more built-in functions, such as a matrix editor, complex number support, an equation solver, user-defined menus, and basic graphing capabilities (the 42S can draw graphs only by programs). Additionally, it features a two-line dot matrix display, which made stack manipulation easier to understand.
Production of the 42S ended in 1995.[1]
Specifications
- Series: Pioneer
- Code Name: Davinci
- Introduction: 1988-10-31
- 64 KB of ROM
- 8 KB of RAM
- Functions: Over 350
- Expandability: Officially no other than IR printing (32 KB memory upgrade[2] and over-clocking hardware[3] hacks are possible)
- Peripherals: HP 82240A infrared printer
Features
- All basic scientific functions (including hyperbolic functions)
- Statistics (including curve fitting and forecasting)
- Probability (including factorial, random numbers and Gamma function)
- Equation solver (root finder) that can solve for any variable in an equation
- Numerical integration for calculating definite integrals
- Matrix operations (including a matrix editor, dot product, cross product and solver for simultaneous linear equations)
- Complex numbers (including polar coordinates representation)
- Vector functions
- Named variables, registers and binary flags
- Graphic display with graphics functions and adjustable contrast
- Menus with submenus and mode settings (also custom programmable) that use the bottom line of the display to label the top row of keys
- Sound (piezoelectric beeper)
- Base conversion, integer arithmetic and binary and logic manipulation of numbers in binary, octal, decimal and hexadecimal systems
- Catalogs for reviewing and using items stored in memory
- Programmability (keystroke programming with branching, loops, tests and flags)
- The ability to run programs written for the HP-41C series of calculators
Programming
The HP-42S is keystroke-programmable, meaning that it can remember and later execute sequences of keystrokes to solve particular problems of interest to the user. The HP-42S uses a superset of the HP-41CX FOCAL language.
All programs are stored in one continuous program space, and may be created and edited by switching to programming mode, using the PRGM key. Subroutines are enclosed in LBL/Label (name of subroutine) and RTN/Return ( halts execution unless it is in a subroutine in which case it returns to the caller). Keystrokes (of functions) are enclosed between LBL and RTN or .END.
In a running program, a GTOlabel causes program execution to branch to the specified label and continue running at that line.Executing a GTO instruction from the keyboard moves the program pointer to the corresponding label. No program lines are executed.
XEQ is used in much the same way with one important difference: after an XEQ instruction has transferred execution to the specified label, the next RTN (return) or END instruction causes the program to branch back to the instruction that immediately follows the XEQ instruction.Programs/Subroutines can also be executed with the help XEQlabel (Execute) key. Important Difference is that XEQ executes the label and returns to previous subroutine and continues execution from the line following XEQ,whereas GOTO branches to the label specificied and doesn't return back.
GTO.. packs the current subroutines and moves to new program space.GTO.nnnn can be used to reach a particular line of program.
Programming examples
A simple program to calculate circumference of circle
Step | Instruction | Comment |
---|---|---|
00 | { 6-Byte Prgm } | |
01 | LBLCIR | Start of program "CIR" |
02 | PI | Puts π on the stack |
03 | INPUTR | Prompts for Value of R and stores it in R |
04 | X↑2 | Squares the value in X register |
05 | × | Multiplies values in X and Y register |
END or RTN | Returns control (and result in X) to either the user or to a calling program. |
Program instructions like STOP, PROMPT, INPUT halt the program execution,which can be continued by pressing R/S.
VIEW is used to view contents of a register,For example R in the above example.
Using Integral and Equation Solver
It is necessary to write a program or subroutine that evaluates f(x) for the function which needs to be solved or integrated. Variables used in program should be declared using MVAR
Here is a sample program to solve the equation °F = (9/5×°C) + 32
Step | Instruction | Comment |
---|---|---|
00 | { 31-Byte Prgm } | |
01 | LBLTEMP | Start of program "TEMP" |
02 | MVARF | Declares F as a variable for solver |
03 | MVARC | Declares C as a variable for solver |
04 | RCLF | Recall F |
05 | 9 | |
06 | 5 | |
07 | ÷ | |
08 | RCLC | Recall C |
09 | × | |
10 | - | |
11 | 32 | |
12 | - | |
END or RTN | Returns control (and result in X) to either the user or to a calling program. |
After, accessing the solver using Shift 7 (SOLVER ), select program TEMP.
In a similar way, expressions can be integrated. After selecting the variable of integration, enter the lower limit and then press on LLIM, similarly input ULIM (upper limit) and ACC (accuracy).
Emulators
HP 42s can be accessed through Android Emulators like Emu42 and Free42.
WP 34s
WP 34S project uses a modern HP financial calculator HP 30b as the starting point to create an advanced scientific RPN calculator. It is a more powerful scientific (non-graphing) calculator compared to the original HP 42s.[4]
Functionality
- Euler's Beta and Riemann's Zeta functions, Bernoulli and Fibonacci numbers, Lambert's W, the error function as well as Chebyshev's, Hermite's, Laguerre's and Legendre's orthogonal polynomials, and testing for primality,
- Many statistical distributions and their inverses like Poisson, Binomial, Geometric as well as Cauchy-Lorentz, Exponential, Logistic, Weibull for reliability analysis, Lognormal and Gaussian with arbitrary means and standard deviations,
- Programmable sums and products, first and second derivatives
Programmability
- RPN keystroke programmable à la HP-41 - up to 925 steps in RAM - numeric and/or alpha labels, thousands of steps burnable into flash banks.
- Externally programmable by developers via JTAG interface
See also
- FOCAL character set
- Comparison of HP graphing calculators
- HP calculators
- List of Hewlett-Packard pocket calculators
- NOMAS (support)
References
- ^ "HP-42S". Museum of HP Calculators. Retrieved 2016-10-27.
- ^ Hosoda, Takayuki (2007-10-10). "Upgrading the memory of the HP 42S to 32KB". Archived from the original on 2017-09-17. Retrieved 2011-08-12.
- ^ HP 42S Easy Double Speed / Turbo Mode for Calculator and Programs, retrieved 2022-08-05
- ^ https://commerce.hpcalc.org/34s.php
Further reading
- HP-42S RPN Scientific Calculator – Owner's Manual (PDF) (1 ed.). Corvallis, OR, USA: Hewlett-Packard Co. June 1988. 00042-90001. Archived (PDF) from the original on 2017-09-17. Retrieved 2017-09-17.
- HP-42S RPN Scientific Calculator – Programming Examples and Techniques (PDF) (1 ed.). Hewlett-Packard. July 1988. 00042-90020, 00042-90019. Archived (PDF) from the original on 2017-12-19. Retrieved 2017-12-19.
- Strapasson, José Lauro; Jones, Russ (January 2010). An Alternative HP-42S/Free42 Manual (PDF). 0.7. Archived (PDF) from the original on 2017-09-17. Retrieved 2017-09-17.
- HP-42S Quick Reference Guide (1 ed.). Corvallis, OR, USA, Dex Smith. October 1988. 00042-92222E.
- Horn, Joseph K. (2017-08-23) [1988-11-09]. "HP-42S Owner's Manual Addendum: Hidden Matrix Functions". Archived from the original on 2017-09-17. Retrieved 2017-09-17.
- "DM42 User Manual". 3.17. SwissMicros GmbH. 2020-10-21 [2016]. Archived from the original on 2020-10-05. Retrieved 2020-10-21.
External links
- SwissMicros DM42
- HP-42S intro on hpcc.org
- HP-42S page on hpmuseum.org
- HP-42S resources on hp42s.com (defunct as of July 2017)
- HP-42S description on rskey.org
- HP-42S description on thimet.de
- Free42 for Android by Thomas Okken, an Open Source project.
- Okken, Thomas (2011-04-20). "Free42, A HP-42S Calculator Simulator". Retrieved 2011-08-12.